LYNDE #3
API 3508103585 · Lincoln County, Oklahoma
Completion
Oklahoma files 1 completion report for this well. One carries a production test the operator filed.
Completion 7
STRAIGHT HOLEACGASInterval
| Formation | Produced | Perforated (ft) | Treatment |
|---|---|---|---|
| HUNTON | GAS | 4,076–4,107 | Acid |
Production tests
| Tested | Oil (bbl/d) | Gas (MCF/d) | Water (bbl/d) | Gravity (°API) | Shut-in (psi) | Choke |
|---|---|---|---|---|---|---|
| 1957-12-27 | 88 | 0 | 40 | 22 | 0 | — |
| 2003-09-20 | 3 | 0 | 33 | 20 | 0 | — |
| 2006-12-05 | 3 | 0 | 30 | — | 0 | — |
| 2025-09-01 | 0 | 10 | 60 | — | 0 | — |
A production test is one measurement the operator made on one day and filed with Oklahoma. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Oklahoma records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Oklahoma did not file, or one it filed outside any physically possible range.
Casing
| String | Size (in) | Weight (lb/ft) | Grade | Set (ft) | Cement (sacks) |
|---|---|---|---|---|---|
| PRODUCTION | 5 1/2 | 14 | J-55 | 4,281 | 150 |
| SURFACE | 10 3/4 | — | J-55 | 1,314 | 120 |
Drilling permits
Oklahoma files 6 applications to drill this well, naming 12 target formations. A permit records what an operator asked to do, not what it did. A target formation is where the operator aimed, and the hole may have missed it, stopped short of it or never been drilled.
Filed 2003-07-03
WRARCTarget formation
| Formation | Expected top (ft) |
|---|---|
| WILCOX 1 | 4,250 |
An expected top is the depth the operator predicted before drilling, on the application it filed with Oklahoma. It is not a measurement of where the formation was found.
Filed 2004-11-30
WRARCTarget formation
| Formation | Expected top (ft) |
|---|---|
| HUNTON | 4,065 |
An expected top is the depth the operator predicted before drilling, on the application it filed with Oklahoma. It is not a measurement of where the formation was found.
Filed 2006-01-13
WRARCTarget formation
| Formation | Expected top (ft) |
|---|---|
| HUNTON | 4,064 |
An expected top is the depth the operator predicted before drilling, on the application it filed with Oklahoma. It is not a measurement of where the formation was found.
Filed 2006-04-27
WRARCTarget formations
| Formation | Expected top (ft) |
|---|---|
| LAYTON | 1,800 |
| CLEVELAND | 2,100 |
| PRUE | 2,915 |
| SKINNER | 3,050 |
| RED FORK | 3,280 |
| HUNTON | 4,064 |
| VIOLA | 4,190 |
An expected top is the depth the operator predicted before drilling, on the application it filed with Oklahoma. It is not a measurement of where the formation was found.
Filed 2009-02-18
WRARCStraight holeTarget formations
| Formation | Expected top (ft) |
|---|---|
| WILCOX 1 | 4,250 |
| WILCOX 2 | 4,280 |
An expected top is the depth the operator predicted before drilling, on the application it filed with Oklahoma. It is not a measurement of where the formation was found.
Filed 2025-07-17
Location
35.602763, -96.652638
Every well in Lincoln County, Oklahoma
Oklahoma state record, from OK_wells_rbdms-wells.parquet. Corpus built 2026-09-11.