Olympian 41-3635-23S

API 43013541120000 · Duchesne County, Utah · NORTH MYTON BENCH field

POW
API
43013541120000
Operator
SM Energy Company
County
Duchesne
Measured depth
21,047 ft
True vertical depth
10,395 ft

Production

17 monthly filings with Utah, Jan 2025 to May 2026. Each product is in its own unit and the four are never added.

Cumulative oil
36,193 bbl
Cumulative gas
41,012 MCF
Cumulative water
126,513 bbl
PeriodOil (bbl)Gas (MCF)Water (bbl)Days
May 20261,7051,0816,00331
Apr 20261,5921,5615,79530
Mar 20261,7631,8076,58231
Feb 20261,7301,7016,28728
Jan 20261,9271,7717,06231
Dec 20252,0621,9557,57431
Nov 20252,1202,6217,26930
Oct 20252,3862,8078,48431
Sep 20252,5033,4478,76230
Aug 20252,4073,2808,64331
Jul 20252,3572,7418,36331
Jun 20252,4582,9248,85230
May 20252,9953,71110,35931
Apr 20251,4331,2603,28013
Mar 20251,3411,5504,68917
Feb 20252,3822,9558,32428
Jan 20253,0323,84010,18531

A dash is a period the well filed with no volume for that product. This corpus holds Utah’s series from 2025; the Division publishes earlier years in a separate set of files.

Wellbore

Utah holds the directional survey of this hole as it was drilled.

Deepest station
21,059 ft
True vertical depth
10,538 ft
Reach from well head (derived)
10,860 ft
Bearing (derived)
282°
Stations shown
20

Utah filed 225 stations for this well. The 20 shown are the ones that carry the shape: every station left out lies within 25 ft of the line drawn through the ones kept. The reach and bearing are derived from two points Utah filed. Neither is a figure the operator reported.

Work history

Utah files 1 record of work done on this well — each drill, plug, deepening, re-entry, re-perforation and recompletion, with the depths reached. One carries a production test the operator filed afterwards.

DRILL

HORIZONTALDRL
Spudded
2021-07-14
First production
2022-10-06
Measured depth
21,059 ft
True vertical depth
10,538 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
2022-10-191,2391,0522,142———

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

Location

40.264751, -110.160225

40.26475, -110.16022 · Surface location as filed with Utah

Every well in Duchesne County, Utah

Utah state record, from UT_wells_Wells.parquet. Corpus built 2026-09-11.