Aneth U F326

API 43037302320000 · San Juan County, Utah · GREATER ANETH field

POW
API
43037302320000
Operator
Elk Operating Services, LLC
County
San Juan
Measured depth
5,710 ft

Production

18 monthly filings with Utah, Jan 2025 to Jun 2026. Each product is in its own unit and the four are never added.

Cumulative oil
6,806 bbl
Cumulative gas
29,410 MCF
Cumulative water
101,124 bbl
PeriodOil (bbl)Gas (MCF)Water (bbl)Days
Jun 20263808335,52730
May 20263421,0805,44531
Apr 20263711,1375,52330
Mar 20263789855,77331
Feb 20263137765,23228
Jan 20263321,1225,03131
Dec 20253599165,13931
Nov 20253128675,41830
Oct 20253698296,00631
Sep 20253588785,79330
Aug 20253932,0825,50631
Jul 20253021,2615,25531
Jun 20252988715,35430
May 20254342,7495,72831
Apr 20254483,1325,50530
Mar 20254563,3406,54731
Feb 20254573,2755,52728
Jan 20255043,2776,81531

A dash is a period the well filed with no volume for that product. This corpus holds Utah’s series from 2025; the Division publishes earlier years in a separate set of files.

Work history

Utah files 5 records of work done on this well — each drill, plug, deepening, re-entry, re-perforation and recompletion, with the depths reached. 5 carry a production test the operator filed afterwards.

DRILL

VERTICALPOW
Completed
1975-08-09
First production
1975-08-09
Measured depth
5,803 ft
True vertical depth
5,803 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1975-08-0912917638038.8——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1997-02-26
Completed
1997-04-28
First production
1997-04-29
Measured depth
7,383 ft
True vertical depth
5,649 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1997-04-29631261,03440——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1997-02-26
Completed
1997-04-28
First production
1997-04-29
Measured depth
7,258 ft
True vertical depth
5,640 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1997-04-29631261,03440——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1997-02-26
Completed
1997-04-28
First production
1997-04-29
Measured depth
7,324 ft
True vertical depth
5,599 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1997-04-29631261,03440——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1997-02-26
Completed
1997-04-28
First production
1997-04-29
Measured depth
7,222 ft
True vertical depth
5,590 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1997-04-29631261,03440——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

Location

37.278313, -109.252202

37.27831, -109.25220 · Surface location as filed with Utah

Every well in San Juan County, Utah

Utah state record, from UT_wells_Wells.parquet. Corpus built 2026-09-11.