Aneth Unit H325

API 43037302390000 · San Juan County, Utah · GREATER ANETH field

POW
API
43037302390000
Operator
Elk Operating Services, LLC
County
San Juan

Production

18 monthly filings with Utah, Jan 2025 to Jun 2026. Each product is in its own unit and the four are never added.

Cumulative oil
20,190 bbl
Cumulative gas
32,264 MCF
Cumulative water
85,858 bbl
PeriodOil (bbl)Gas (MCF)Water (bbl)Days
Jun 20269851,7674,64030
May 20268902,5824,57131
Apr 20269462,0464,63730
Mar 20269521,5334,84631
Feb 20268021,5224,39228
Jan 20268321,5694,22331
Dec 20259101,4414,31431
Nov 20258031,9094,54830
Oct 20259491,8575,04231
Sep 20259091,5204,86430
Aug 20259151,5534,77131
Jul 20258452,3284,78631
Jun 20251,3462,1995,53230
May 20251,6841,3435,91931
Apr 20251,7401,9985,68830
Mar 20251,7452,4676,76531
Feb 20251,7702,0115,23528
Jan 20251,1676191,08531

A dash is a period the well filed with no volume for that product. This corpus holds Utah’s series from 2025; the Division publishes earlier years in a separate set of files.

Work history

Utah files 6 records of work done on this well — each drill, plug, deepening, re-entry, re-perforation and recompletion, with the depths reached. 5 carry a production test the operator filed afterwards.

DRILL

VERTICALPOW
Completed
1975-11-06
First production
1975-11-06
Measured depth
5,747 ft
True vertical depth
5,747 ft

DEEPEN

HORIZONTALPOW
Spudded
1998-02-04
Completed
1998-03-23
First production
1998-03-23
Measured depth
7,053 ft
True vertical depth
5,580 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1998-03-23140541,335———

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1998-02-04
Completed
1998-03-23
First production
1998-03-23
Measured depth
6,682 ft
True vertical depth
5,570 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1998-03-23140541,335———

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1998-02-04
Completed
1998-03-23
First production
1998-03-23
Measured depth
7,681 ft
True vertical depth
5,541 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1998-03-23140541,335———

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1998-02-04
Completed
1998-03-23
First production
1998-03-23
Measured depth
7,013 ft
True vertical depth
5,539 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1998-03-23140541,335———

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1998-02-04
Completed
1998-03-23
First production
1998-03-23
Measured depth
7,653 ft
True vertical depth
5,521 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1998-03-23140541,335———

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

Location

37.278113, -109.224822

37.27811, -109.22482 · Surface location as filed with Utah

Every well in San Juan County, Utah

Utah state record, from UT_wells_Wells.parquet. Corpus built 2026-09-11.