Aneth Unit F126

API 43037303100000 · San Juan County, Utah · GREATER ANETH field

POW
API
43037303100000
Operator
Elk Operating Services, LLC
County
San Juan

Production

18 monthly filings with Utah, Jan 2025 to Jun 2026. Each product is in its own unit and the four are never added.

Cumulative oil
12,947 bbl
Cumulative gas
13,062 MCF
Cumulative water
89,650 bbl
PeriodOil (bbl)Gas (MCF)Water (bbl)Days
Jun 20263787741,94530
May 20263401,0031,91631
Apr 20263691,0561,94330
Mar 20263769152,03131
Feb 20268268315,84628
Jan 20268641,2025,62131
Dec 20259439825,74231
Nov 20258159296,05330
Oct 20259668886,71031
Sep 20259379416,47330
Aug 20251901801,2937
Jul 20258282936,34131
Jun 20258092026,46030
May 20251,0556386,91131
Apr 20251,0096686,41530
Mar 20257124656,54731
Feb 20257434565,52728
Jan 20257876395,87631

A dash is a period the well filed with no volume for that product. This corpus holds Utah’s series from 2025; the Division publishes earlier years in a separate set of files.

Work history

Utah files 6 records of work done on this well — each drill, plug, deepening, re-entry, re-perforation and recompletion, with the depths reached. 6 carry a production test the operator filed afterwards.

DRILL

VERTICALPOW
Completed
1977-01-17
First production
1977-01-17
Measured depth
5,820 ft
True vertical depth
5,820 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1977-01-191257813541.6——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1997-06-10
Completed
1997-08-15
First production
1997-08-15
Measured depth
7,545 ft
True vertical depth
5,648 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1997-08-1479219953943——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1997-06-10
Completed
1997-08-15
First production
1997-08-15
Measured depth
7,120 ft
True vertical depth
5,639 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1997-08-1479219953943——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1997-06-10
Completed
1997-08-15
First production
1997-08-15
Measured depth
7,481 ft
True vertical depth
5,603 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1997-08-1479219953943——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1997-06-10
Completed
1997-08-15
First production
1997-08-15
Measured depth
6,497 ft
True vertical depth
5,588 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1997-08-1479219953943——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1997-06-10
Completed
1997-08-15
First production
1997-08-15
Measured depth
7,061 ft
True vertical depth
5,595 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1997-08-1479219953943——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

Location

37.285988, -109.251934

37.28599, -109.25193 · Surface location as filed with Utah

Every well in San Juan County, Utah

Utah state record, from UT_wells_Wells.parquet. Corpus built 2026-09-11.