Aneth U F322

API 43037303450000 · San Juan County, Utah · GREATER ANETH field

POW
API
43037303450000
Operator
Elk Operating Services, LLC
County
San Juan
Measured depth
5,933 ft

Production

18 monthly filings with Utah, Jan 2025 to Jun 2026. Each product is in its own unit and the four are never added.

Cumulative oil
16,189 bbl
Cumulative gas
182,501 MCF
Cumulative water
225,953 bbl
PeriodOil (bbl)Gas (MCF)Water (bbl)Days
Jun 20267322,68111,94130
May 20266543,11011,76531
Apr 20266902,67611,93230
Mar 20266892,12412,47231
Feb 20265681,58911,30428
Jan 20266072,50410,86831
Dec 20256572,12411,10231
Nov 20255701,85311,70530
Oct 20256802,05712,97631
Sep 20256752,62312,51730
Aug 20256114,61310,10631
Jul 20254295,5348,72331
Jun 20251,09617,68412,38730
May 20251,62928,21615,09031
Apr 20251,80735,75014,50330
Mar 20251,60228,06117,24931
Feb 20251,34521,35214,56128
Jan 20251,14817,95014,75231

A dash is a period the well filed with no volume for that product. This corpus holds Utah’s series from 2025; the Division publishes earlier years in a separate set of files.

Wellbore

Utah holds the directional survey of this hole as it was drilled.

Deepest station
5,886 ft
True vertical depth
5,880 ft
Reach from well head (derived)
81 ft
Bearing (derived)
31°
Stations shown
2

Utah filed 32 stations for this well. The 2 shown are the ones that carry the shape: every station left out lies within 25 ft of the line drawn through the ones kept. The reach and bearing are derived from two points Utah filed. Neither is a figure the operator reported.

Work history

Utah files 2 records of work done on this well — each drill, plug, deepening, re-entry, re-perforation and recompletion, with the depths reached. One carries a production test the operator filed afterwards.

DRILL

VERTICALPOW
Completed
1977-11-03
First production
1977-11-03
Measured depth
5,951 ft
True vertical depth
5,951 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1977-11-033422151543.7——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

DIRECTIONALNEW
Measured depth
5,912 ft
True vertical depth
5,906 ft

Location

37.293439, -109.270105

37.29344, -109.27011 · Surface location as filed with Utah

Every well in San Juan County, Utah

Utah state record, from UT_wells_Wells.parquet. Corpus built 2026-09-11.