Aneth U K131

API 43037306470000 · San Juan County, Utah · GREATER ANETH field

POW
API
43037306470000
Operator
Elk Operating Services, LLC
County
San Juan
Measured depth
5,835 ft

Production

18 monthly filings with Utah, Jan 2025 to Jun 2026. Each product is in its own unit and the four are never added.

Cumulative oil
38,194 bbl
Cumulative gas
261,982 MCF
Cumulative water
485,875 bbl
PeriodOil (bbl)Gas (MCF)Water (bbl)Days
Jun 20261,9657,00425,48630
May 20261,82110,23825,10931
Apr 20261,8928,11025,46730
Mar 20262,50921,19621,33131
Feb 20262,21324,65218,18428
Jan 20262,28125,41717,48331
Dec 20252,44923,33717,85931
Nov 20252,05116,69125,13130
Oct 20252,0695,65233,07031
Sep 20252,0539,36732,86430
Aug 20252,14811,03932,52431
Jul 20251,92116,41732,48131
Jun 20251,98112,54533,09330
May 20252,2547,66035,40331
Apr 20252,39811,40034,02630
Mar 20252,52914,33138,12031
Feb 20251,79516,59418,73228
Jan 20251,86520,33219,51231

A dash is a period the well filed with no volume for that product. This corpus holds Utah’s series from 2025; the Division publishes earlier years in a separate set of files.

Wellbore

Utah holds the directional survey of this hole as it was drilled.

Deepest station
5,812 ft
True vertical depth
5,800 ft
Reach from well head (derived)
153 ft
Bearing (derived)
238°
Stations shown
5

Utah filed 86 stations for this well. The 5 shown are the ones that carry the shape: every station left out lies within 25 ft of the line drawn through the ones kept. The reach and bearing are derived from two points Utah filed. Neither is a figure the operator reported.

Work history

Utah files 2 records of work done on this well — each drill, plug, deepening, re-entry, re-perforation and recompletion, with the depths reached. 2 carry a production test the operator filed afterwards.

DRILL

VERTICALPOW
Completed
1981-11-12
First production
1981-11-12
Measured depth
5,800 ft
True vertical depth
5,779 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1981-11-12306627242.5——

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

DIRECTIONALNEW
Measured depth
5,812 ft
True vertical depth
5,799 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
2023-01-01——————

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

Location

37.271169, -109.215557

37.27117, -109.21556 · Surface location as filed with Utah

Every well in San Juan County, Utah