Ratherford Unit 19-31

API 43037310470000 · San Juan County, Utah · GREATER ANETH field

POW
API
43037310470000
Operator
Elk Operating Services, LLC
County
San Juan
Measured depth
5,700 ft

Production

18 monthly filings with Utah, Jan 2025 to Jun 2026. Each product is in its own unit and the four are never added.

Cumulative oil
11,760 bbl
Cumulative gas
685 MCF
Cumulative water
126,065 bbl
PeriodOil (bbl)Gas (MCF)Water (bbl)Days
Jun 202657506,02730
May 202658506,54531
Apr 202663206,39930
Mar 202666306,91331
Feb 202658206,52128
Jan 202666506,78531
Dec 202566117,53131
Nov 202565067,13530
Oct 2025667267,49131
Sep 2025639637,16430
Aug 2025657936,89931
Jul 2025674817,05231
Jun 2025631686,54130
May 2025745417,84631
Apr 2025668217,30130
Mar 20257111087,69131
Feb 2025666807,14728
Jan 2025689977,07731

A dash is a period the well filed with no volume for that product. This corpus holds Utah’s series from 2025; the Division publishes earlier years in a separate set of files.

Work history

Utah files 3 records of work done on this well — each drill, plug, deepening, re-entry, re-perforation and recompletion, with the depths reached. 2 carry a production test the operator filed afterwards.

DRILL

VERTICALPOW
Completed
1984-10-16
First production
1984-10-16
Measured depth
5,604 ft
True vertical depth
5,604 ft

DEEPEN

HORIZONTALPOW
Spudded
1998-10-07
Completed
1998-11-10
First production
1998-11-28
Measured depth
7,046 ft
True vertical depth
5,524 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1998-11-299943281———

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

DEEPEN

HORIZONTALPOW
Spudded
1998-10-07
Completed
1998-11-10
First production
1998-11-28
Measured depth
7,190 ft
True vertical depth
5,541 ft

Production test

TestedOil (bbl/d)Gas (MCF/d)Water (bbl/d)Gravity (°API)Shut-in (psi)Choke
1998-11-299943281———

A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.

Location

37.215009, -109.321540

37.21501, -109.32154 · Surface location as filed with Utah

Every well in San Juan County, Utah