Aneth Unit E218SE
API 43037313850000 · San Juan County, Utah · GREATER ANETH field
Production
18 monthly filings with Utah, Jan 2025 to Jun 2026. Each product is in its own unit and the four are never added.
| Period | Oil (bbl) | Gas (MCF) | Water (bbl) | Days |
|---|---|---|---|---|
| Jun 2026 | 301 | 3,119 | 887 | 30 |
| May 2026 | 287 | 3,856 | 874 | 31 |
| Apr 2026 | 320 | 4,855 | 886 | 30 |
| Mar 2026 | 330 | 4,832 | 926 | 31 |
| Feb 2026 | 312 | 4,598 | 840 | 28 |
| Jan 2026 | 350 | 5,106 | 807 | 31 |
| Dec 2025 | 329 | 4,658 | 825 | 31 |
| Nov 2025 | 340 | 4,423 | 870 | 30 |
| Oct 2025 | 401 | 4,551 | 1,060 | 31 |
| Sep 2025 | 407 | 3,674 | 1,121 | 30 |
| Aug 2025 | 494 | 4,121 | 1,100 | 31 |
| Jul 2025 | 459 | 4,217 | 1,099 | 31 |
| Jun 2025 | 549 | 4,797 | 1,119 | 30 |
| May 2025 | 579 | 5,965 | 1,197 | 31 |
| Apr 2025 | 551 | 6,781 | 1,151 | 30 |
| Mar 2025 | 511 | 5,298 | 1,369 | 31 |
| Feb 2025 | 364 | 4,826 | 1,126 | 28 |
| Jan 2025 | 387 | 5,977 | 1,167 | 31 |
A dash is a period the well filed with no volume for that product. This corpus holds Utah’s series from 2025; the Division publishes earlier years in a separate set of files.
Work history
Utah files 2 records of work done on this well — each drill, plug, deepening, re-entry, re-perforation and recompletion, with the depths reached. 2 carry a production test the operator filed afterwards.
DRILL
VERTICALPOWProduction test
| Tested | Oil (bbl/d) | Gas (MCF/d) | Water (bbl/d) | Gravity (°API) | Shut-in (psi) | Choke |
|---|---|---|---|---|---|---|
| 1989-11-07 | 36 | 27 | 422 | 42.1 | — | — |
A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.
DEEPEN
DIRECTIONALPOWProduction test
| Tested | Oil (bbl/d) | Gas (MCF/d) | Water (bbl/d) | Gravity (°API) | Shut-in (psi) | Choke |
|---|---|---|---|---|---|---|
| 2012-12-19 | 25 | 0 | 201 | 40 | — | — |
A production test is one measurement the operator made on one day and filed with Utah. It is not a monthly average and it does not describe how the well produced afterwards. The choke size is shown exactly as filed: Utah records it in inches on some reports and in sixty-fourths of an inch on others, and names the unit on neither. A dash is a measurement Utah did not file, or one it filed outside any physically possible range.
Location
37.309381, -109.327038
Every well in San Juan County, Utah